A Poodle,6 years old, male, 3.5kg, suffered from a fracture of right distal radius and ulna, a comminuted fracture of femur and the dislocation of wrist joint more than three weeks. The muscles were atrophied. We fixed the wrist joint by using the BlueSAO HyProtect-PRCL- S6.5mmantimicrobial plasma coating locking plate and fixed the femur with BlueSAO PRCL-S6.5mm locking plate+φ2.0 intramedullary pin. The surgery was completed successfully. Hope the guy recovery soon!
The MicroSilver antimicrobial plasma coatings come from German Bio-Gate company. This antimicrobial plasma coating can release Ag+( silver ion) in body more than 100 days for resisting infection to kill 99.9 percent of bacteria.
Thanks for Dr. Li from Chongqing Taihe Animal Hospital bringing us the case.
Orthopedic Instruments We Use BlueSAO