#Cat# #7Months# #2.5kg# #tibia-other position-comminuted fracture#

20220718-【Comminuted fracture of tibia】A cat, fixed with HyProtect-PRCL®-S antimicrobial plasma coating plate system successfully

Kunming Yijia Animal HospitalDr. Li2022-09-14 468

A cat, 7 months old, female, 2.5kg, suffered from a comminuted fractureof tibiaand a dislocation of sacroiliac joint. We fixedthe sacroiliac joint by using φ2.4mmlag screwand fixed the tibia by using BlueSAO HyProtect-PRCL®-5mm and HyProtect-PRCL®-6mm antimicrobial plasma coating locking plates during the surgery. The surgery was successful and we look forward to a speedy recovery.

Hyprotect silver ion antibacterial coating is a black technology (a technology that is far more advanced than those of the real world) from Bio-Gate, Germany, specifically for fracture types with a high risk of infection (infectious fracture repair, open fracture, etc.). It can continuously precipitate silver ions in the body for more than 100 days, and can be effective for long-term antibacterial, with an antibacterial rate of 99.9%.

Thanks to Dr. Li from Kunming Yijia Animal Hospital of Yunnan province bringing us the case.



Orthopedic Instruments We Use BlueSAO