A cat, 8 months old, female, 3kg, jumped down from a high place, caused fractures of middlehumerusand proximalradius. We fixed the humerus by using BlueSAO PRCL®-S-6.5mm pure titanium locking plate and fixed the radius by using BlueSAO PRCL®-Mini-4mm pure titanium locking plate. The surgery was successful and we look forward to a speedy recovery.
Thanks to Dr. Han from Harbin Song Yisheng Animal Hospital of Heilongjiang province bringing us the case.
Orthopedic Instruments We Use BlueSAO