#Dog# #24Months# #12kg# #tibia-distal-open fracture#

20181220 -【Open fracture of distal tibia】A Chinese rural dog, fixed with HyProtect-PRCL-M antimicrobial plasma coating plate system successfully

Maoming Mingya Animal HospitalDr. Xu2019-01-14 1331

A Chinese rural dog,2 years old,female,12kg,nipped by a hunting clip,caused an open fracture of distal tibia.Due tothe open fracturewith the high risky of infection,the ordinary bone plate can not resist the infection.So we decided to fixed the tibia with the BlueSAO HyProtect-PRCL-M antimicrobial plasma coating locking plate.

Due tothe master didn’t let the dog wear a Elizabethan collar to prevent her from licking the wound,the wound remained open for more than nine months since the 16th day after the surgery.Fortunately,in such an open environment,this antimicrobial plasma coating release Ag+( silver ion) in body continuously for resisting infection,and the bone fracture is also healing magically.Without the antimicrobial plasma coating plate, there is no chance of successful healing.

Now this guy has recovered and the plate has been removed .

Thanks for Dr.Xu from Maoming Mingya Animal Hospital of Guangdong province bringing us the case.



Orthopedic Instruments We Use BlueSAO