#Cat# #24Months# #3.4kg# #femur-other position-comminuted fracture#

20230927- [Femoral Fracture] Golden Progressive Cat, Successfully Fixed with HyProtect-PRCL-S Silver Ion Antibacterial Bone Plate System

Shanghai Shengtai Pet HospitalDr. Guan Narisu2023-10-17 162

A golden shaded British shorthair cat, nickname: Jiangjiang, 2 years old, male, 3.4kg.

Medical history: the cat was suffered from the comminuted fracture on the femur of the left hind limb due to the external force after falling from the 7th floor. His owner promptly brought him to our hospital. We did a DR showing an open comminuted fracture and rupture, which is expected to be difficult to operate with a long postoperative recovery period. During the surgery, BlueSAO HyProtect-PRCL-5.5mm and 6.5mm silver ion antimicrobial plates were used for internal fixation, and BlueSAO's S-VETOSS artificial bone imported from Canada was implanted to stimulate bone formation and healing. The surgery was completed successfully. Best wishes for an early recovery.

Thanks to Dr. Guan Narisu (Shanghai Shengtai Pet Hospital) for sharing the clinical case of SVETOSS artificial bone and PRCL locking plate system.

Pet photo:



Orthopedic Instruments We Use BlueSAO