A Yorkshire Terrier, 5 years old, male, 1.7kg, presented with lameness due to a fall, and the imaging diagnosis showed a rupture of cranial cruciate ligament of the right hind limb, and the drawer test result was positive. We performed a TPLO surgery by fixing it with BlueSAO TPLO - 4mm L-type pure titanium locking plate. The surgery was completed successfully. Best wishes for an early recovery.
Thanks to Dr. Shao Zhiwei (Wuhan Weiwei Animal Hospital) for sharing the clinical case of BlueSAO TPLO locking plate system.
Orthopedic Instruments We Use BlueSAO