A maine coon cat, nickname: Soba, 2 years old, male, 7kg, suffered from bilateral femoral neck fracture. After examination, we decided to perform a THR surgery on the cat’s right femoral neck first. Intraoperatively, we adopted a φ10mm cemented cup, a #3 femoral stem, and a φ8mm (+0) femoral head of BlueSAO Micro & Nano Hip Replacement System for replacement. Considering that the cat had recovered well 38 days after undergoing surgery on the right femoral neck, the decision was made to carry out a THR surgery on the left femoral neck.
Thanks to Dr. Tao Weifu (Tianmuli Referral Center of Hangzhou Hongtai Pet Hospital) for sharing the clinical case of BlueSAO Hip Replacement System.
Orthopedic Instruments We Use BlueSAO