#Cat# #6Months# #2kg# #tibia-middle-transverse fracture# #fibula-middle-transverse fracture#

20240831- [Transverse Fracture of Middle Tibiofibula] A Felis Catus, Fixed with PRCL-S System for Internal Fixation Successfully

Hefei Jiujiu Pet HospitalDr.Zhang Li2024-09-07 30

A felis catus, 6 months old, female, 2kg, suffered from the transverse fracture of middle tibiofibula due to being stuck in a cage. As such, we decided to perform the internal fixation surgery. The cat’s tibiofibula was fixed with BlueSAO PRCL®-5mm pure titanium locking plate for internal fixation. The surgery was completed successfully. Best wishes for an early recovery.

Thanks to Dr.Zhang Li (Hefei Jiujiu Pet Hospital) for sharing the clinical case of BlueSAO PRCL® locking plate system.



Orthopedic Instruments We Use BlueSAO