A bichon frise, 6 years old, male, 6.5kg,suffered from the rupture of cranial cruciate ligament due to patellar luxation. As such, we decided to perform a TPLO surgery. The implant was used for internal fixation with BlueSAO TPLO-5.5mm R-type pure titanium locking plate. The dog is recovering well from the surgery. Best wishes for an early recovery.
Thanks to Dr. Shao Zhiwei (Wuhan Weiwei Animal Hospital) for sharing the clinical case of BlueSAO TPLO locking plate system.
Orthopedic Instruments We Use BlueSAO