A maine coon cat, 1 year and 4 months old, male, 6.2kg,was diagnosed with slipped epiphysis of the left femoral head due to abnormal walking of the left hind limb. As such, we decided to perform a THR surgery. During the surgery, we adopted a φ11mm PEEK cemented acetabular cup, a φ8mm+2 femoral head, and a #3 stem of BlueSAO Micro & Nano Bionic Hip Replacement Systemfor replacement. The cat is recovering well from the surgery. Best wishes for an early recovery.
Thanks to Dr. Tao Weifu (Tianmuli Referral Center of Hangzhou Hongtai Pet Hospital) for sharing the clinical case of BlueSAO Micro & Nano Bionic Hip Replacement System.
Note: The number of clinical cases in the title only refers to the BlueSAO THR clinical case statistics released by this official account.