A border collie, 4 years old, female, 16kg,suffered from severe arthritis of the left hip, accompanied by pain and decreased range of motion. As such, we decided to perform a hip replacement. Intraoperatively, a φ21mm bionic cup, a φ16mm PEEK femoral head, a #5 biological stem, and an M+0 femoral neck of BlueSAO Bionic Hip Joint System were adopted for replacement. The surgery was completed successfully, and the dog is recovering very well one week after the surgery. Best wishes for an early recovery.
BlueSAO Hip Replacement System:Non-3D Printed Stem of Mainstream Forging Stem Process! All implants like the acetabular cup, femoral head, femoral neck, and lateral bolt are not 3D printed and have stood the test of time to be safer and more reliable!
Thanks to Dr. Luo Yusheng (Guangzhou YY Veterinary Hospital) for sharing the case of BlueSAO Bionic Hip Joint System.