#Dog# #8Months# #2.5kg# #radius-distal-other fracture# #ulna-distal-other fracture#

20200202-【Fracture of distal radius and ulna】A Pomeranian, fixed with HyProtect-PRCL-S antimicrobial plasma coating plate system successfully

Hefei Ai-Bi Animal HospitalDr. Zhao2020-02-28 2299

A Pomeranian, named Beibei, female, 8 months old, 2.5kg, fell off the sofa half a month ago, caused a fracture of right distal radius and ulna and a hairline fracture of proximal radius.

A hospital did a external fixation for her, but it failed. The skin at her fracture site was severely festered, so we fixed her radius by using the BlueSAO HyProtect-PRCL-S5mmantimicrobial plasma coating locking plate. The MicroSilver antimicrobial plasma coatings come from German Bio-Gate company.

This antimicrobial plasma coating can release Ag+( silver ion) in body more than 100 days for resisting infection.

The surgery was completed successfully. Hope the guy recovery soon!

Thanks for Dr. Zhaofrom Hefei Ai-Bi Animal Hospital of Anhui province bringing us the case.



Orthopedic Instruments We Use BlueSAO