Breed: A cat, weight: 4.5kg, age: 1 year, sex: female
Fractures in this area of the
femoral neck are very common in cats. The characteristics of a cat are small
acetabulum, straight femurs, and large bone marrow cavities. Therefore, in
total hip replacement surgery for cats, small acetabular cups and large femoral
stems are often needed. BlueSAO Micro&Nano Hip System is very suitable for
hip replacement in cats, to the point where I once thought it was tailor-made
for them. Thanks to BlueSAO Micro&Nano Hip System, hip replacement surgery
for cats has become much simpler!
On BlueSAO self-developed iBlueVet
planning software, precise preoperative planning is performed after Marker
calibration of the radiographs. Selection of the appropriate femoral stem
prosthesis and acetabular cup prosthesis. Preoperative planning uses a #2 head-stem
integrated cemented Nano femoral stem and a 10mm bone cemented cup. During the surgery,
the femoral stem prosthesis model is used for testing before deciding on the
final femoral stem prosthesis.
Preoperative X-rays:
Orthopedic Instruments We Use BlueSAO