Breed: Orange cat, Weight: 4.5kg,
Age: 1 year old, Gender: Female
Fracture of the femoral neck is
quite common in cats. The characteristics of cats are small acetabulum,
straight femur and large medullary cavity. Therefore, in total hip replacement
surgery for cats, a small acetabular cup and a large femoral stem are often
required. BlueSAO Micro&Nano Hip Replacement System is very suitable for
feline hip replacement. I even thought it was tailor-made for cats. Thanks to
BlueSAO Micro&Nano Hip Replacement System, feline hip replacement has
become very simple and easy!
In the iBlueVet planning software
independently developed by BlueSAO, precise preoperative planning can be
performed after Marker calibration of X-rays. Suitable femoral stem prostheses
and acetabular cup prostheses can be selected accordingly. Preoperative
planning uses a cemented #2 head-stem integrated femoral stem and a 10mm cemented
cup. The final choice of femoral stem prosthesis will be made after testing
with the femoral prosthesis model during surgery.
Planned implants: #2 cemented
head-stem integrated femoral stem and 10mm cemented cup.
Preoperative
X-ray:
Orthopedic Instruments We Use BlueSAO