A Welsh Corgi dog, 8 years old, female (neutered), 13.5kg.
Medical history: she suffered from a lameness in the left hind limb, which was diagnosed as the rupture of cranial cruciate ligament. As such, we decided to perform a TPLO surgery. Accurate preoperative planning was made by BlueSAO iBlueVet, and she was fixed with BlueSAO TPLO-6.5mm L-type pure titanium locking plate and a #15 saw blade. The surgery was completed successfully. Best wishes for an early recovery.
Thanks to Dr. Han Bo (Dr. Song Pet Hospital of Harbin) for sharing the clinical case of BlueSAO TPLO locking plate system.