#Other# #24Months# #65kg# #radius-other position-spiral fracture#

20240502- [Fracture of Radius and Ulna] An Alpaca, Fixed with PRCL-L System for Internal Fixation Successfully

Tianjin Huating Pet HospitalDr .Li Yongqi2024-05-12 150

An Alpaca, 2 years old, female, 65kg,

presented with a comminuted fracture of the radius, as such, we decided to perform the internal fixation surgery. She was fixed with BlueSAO PRCL®-11mm+10mm pure titanium locking plate, five 2.7mm lag screws and ten locking screws for dual plate internal fixation. The surgery was completed successfully. Best wishes for an early recovery.

Thanks toDr .Li Yongqi (Tianjin Huating Pet Hospital) for sharing the clinical case of BlueSAO PRCL® locking plate system.

BlueSAO PRCL® Locking Plate System: Imported Pure Titanium Guarantees the Quality



Orthopedic Instruments We Use BlueSAO