A felis catus, 3 years old, female, 3kg,suffered from luxation of femoral head due to a fall. As such, we decided to perform a THR surgery on this cat. Intraoperatively, we adopted a φ11mm PEEK cemented cup, a φ8mm+0 femoral head, and a #3 stem of BlueSAO Micro & Nano Bionic Hip Replacement System for replacement. The surgery was completed successfully. Best wishes for an early recovery.
BlueSAO Hip Replacement System: Non-3D Printed Stem of Mainstream Forging Stem Process! All implants like the acetabular cup, femoral head, femoral neck, and lateral bolt are not 3D printed and have stood the test of time to be safer and more reliable!
Thanks to Dr. Shao Zhiwei (Wuhan Ringpai Weiwei Animal Hospital) for sharing the clinical case of BlueSAO Micro & Nano Bionic Hip Replacement System.
Orthopedic Instruments We Use BlueSAO