#Cat# #11Months# #5.3kg# #hip joint-other position-dysplasia# #hip joint-other position-THR#

Case 367: Teacher Du Lang from Kunming Ruipai Hengjia - British Shorthair Cat BlueSAO Micro Bionic Bone Cemented Hip Replacement!

Kunming Ruipai Hengjia Pet HospitalDr. Du Lang2025-07-24 14

British shorthair cat, nickname: Li Gelu, 11 months old, male (not sterilized), weight 5.3Kg.

The left hind limb continued to limp, the affected limb muscle atrophy, clinical examination showed no abnormal knee and tarsal joints, DR suggested left hip dysplasia, and decided to perform hip replacement.

During the operation, the BlueSAOMicro Bionic CementedHip System was used for replacement, and the implant selection was: 13mm PEEK CementedAcetabular Cup, 10mm+2 Femoral Head, #3 CementedFemoral Stem. The operation was successfully completed, and the cat walked normally three days after the operation, and the recovery was very ideal!

"First do no harm" is one of the core principles of medical ethics, emphasizing that medical behavior should give priority to avoiding physical and mental harm to patients. A good surgical process must be less damage to the body of small animals.

There are always specific/special cases, but specific/special cases must never be used as universal treatment principles. We pursue clean total hips, pursue all minimally damaging operations, and strive for painless joints for small animals!

BlueSAO Hip Replacement System: Mainstream forging handle technology in human medicine, not 3D printed handle! Stands the test of time, safer and more reliable!

Special thanks to Mr. Du Lang from Kunming Ruipai Hengjia Pet Hospital for sharing the clinical case of BlueSAO Micro Bionic CementedHip System!



Orthopedic Instruments We Use BlueSAO