Breed:
Maine Cat, Name: Tiger, Age: 1 year old, Sex: Male ( castrated), Weight: 10 kg.
This cat suffered from bilateral femoral head slip
fractures. The pet owner considered the option of total hip replacement. The
decision was made to perform THR on the left side of the affected limb first.
We performed the surgery using BlueSAO cemented Micro&Nano Hip System.
Implants:
#3 cemented femoral stem, 14mm cemented cup, 8mm (+0) femoral head.
The
surgery was relatively uneventful. Imaging results showed good status of the
implants postoperatively. Recovery was excellent.
The results of the postoperative review at three weeks
showed that the muscle mass of the operated side was significantly greater than
that of the non-operated side. A total hip replacement was performed on the
right side. Implants: #3 cemented femoral stem, 14mm cemented cup, 8mm (+2) femoral
head. The surgery went well and the postoperative recovery was good!
Pet photo: