A Chinese rural dog, named Huihui, 5 months old, female, 13kg, hit by a car, caused a closed fracture of right radius and ulna and an open fracture of left radius and ulna. So we fixed the right radius with BlueSAO PRCL-L11mm locking plate and fixed the left radius with the BlueSAO HyProtect-PRCL-L11mm antimicrobial plasma coating locking plate. The MicroSilver antimicrobial plasma coatings come from German Bio-Gate company. This antimicrobial plasma coating can release Ag+( silver ion) in body more than 100 days for resisting infection. The surgery was completed successfully. Hope the guy recovery soon!
Thanks for Dr. Li from Chongqing Taihe Animal Hospital bringing us the case.
Orthopedic Instruments We Use BlueSAO